CONNECT-S-HCL-SM
CONNECT HCL Secondary Occupancy Sensor
Designed for indoor use in dry locations only
Requires primary sensor, CONNECT-P-HCL-SM part number 97216. Up to 4 secondary sensors can be connected to a primary sensor
Low voltage Passive Infrared motion sensor powered by the primary sensor DALI bus
Uses open source IEC 62386 Version 2 standard DALI2 (Digital Addressable Lighting Interface) protocol to control lighting. Requires LED tunable white color changing fixtures with DALI2 compliant Device Type 8 (DT8) drivers.
DALI "broadcast" functionality with the factory settings or can be set to belong to a group for DALI group control
Self-test upon power up
LED indicators for operation feedback and troubleshooting
Masking blinds included to limit degree of motion detection coverage.
Protective wire guard/basket cover available
ROHS and REACH compliant
5 years limited warranty
Indoor applications:
Private and Open Offices
Conference Rooms
School/University Classrooms
Hospital Patient Rooms and Healthcare Spaces
Senior Care and Living Spaces
Type
Part no.
CONNECT-S-HCL-SM
97147
Accessories
Part no.
BSK Ball basket guard / White
92199
Technical data
Operating Voltage: typ. 16 VDC, DALI Bus
Detection area: 360°
Detection range:
Ø 78 ft/24 m across
Ø 26 ft/8 m towards
Ø 20 ft/6.4 m seated
Monitored area (tangential movement):
4844 sqft @ 8.2 ft Mounting height/
450 m² @ 2.5m Mounting height
Mounting height min./ max./recommended:
6.6 ft / 32.8 ft / 8.2 ft /
2 m / 10 m / 2.5 m
Operating temperature: -13 °F to 122 °F/ -25 °C to +50 °C
Maximum number of Secondary sensors:
up to 4 secondary devices in combination with one CONNECT-P-HCL
Pulse interval: 30 sec (in test mode 2 sec during 3 min)
Compliances: ETL listed for the U.S. and Canada (UL STD 60730-1 and CSA STD E60730-1). UL 2043 plenum rated.